New in version 2.4.
Parameter |
Choices/Defaults |
Comments |
---|---|---|
interface
|
|
Full name of interface, i.e. 40GE1/0/22.
|
jumbo_max
|
|
Maximum frame size. The default value is 9216. The value is an integer and expressed in bytes. The value range is 1536 to 12224 for the CE12800 and 1536 to 12288 for ToR switches.
|
jumbo_min
|
|
Non-jumbo frame size threshod. The default value is 1518. The value is an integer that ranges from 1518 to jumbo_max, in bytes.
|
mtu
|
|
MTU for a specific interface. The value is an integer ranging from 46 to 9600, in bytes.
|
state
|
|
Specify desired state of the resource.
|
Note
- name: Mtu test
hosts: cloudengine
connection: local
gather_facts: no
vars:
cli:
host: "{{ inventory_hostname }}"
port: "{{ ansible_ssh_port }}"
username: "{{ username }}"
password: "{{ password }}"
transport: cli
tasks:
- name: "Config jumboframe on 40GE1/0/22"
ce_mtu:
interface: 40GE1/0/22
jumbo_max: 9000
jumbo_min: 8000
provider: "{{ cli }}"
- name: "Config mtu on 40GE1/0/22 (routed interface)"
ce_mtu:
interface: 40GE1/0/22
mtu: 1600
provider: "{{ cli }}"
- name: "Config mtu on 40GE1/0/23 (switched interface)"
ce_mtu:
interface: 40GE1/0/22
mtu: 9216
provider: "{{ cli }}"
- name: "Config mtu and jumboframe on 40GE1/0/22 (routed interface)"
ce_mtu:
interface: 40GE1/0/22
mtu: 1601
jumbo_max: 9001
jumbo_min: 8001
provider: "{{ cli }}"
- name: "Unconfigure mtu and jumboframe on a given interface"
ce_mtu:
state: absent
interface: 40GE1/0/22
provider: "{{ cli }}"
Common return values are documented here, the following are the fields unique to this module:
Key |
Returned |
Description |
---|---|---|
changed
boolean
|
always |
check to see if a change was made on the device
Sample:
True
|
end_state
dict
|
always |
k/v pairs of mtu/sysmtu values after module execution
Sample:
{'jumbo_max': '9000', 'jumbo_min': '8000', 'mtu': '1700'}
|
existing
dict
|
always |
k/v pairs of existing mtu/sysmtu on the interface/system
Sample:
{'jumbo_max': '9216', 'jumbo_min': '1518', 'mtu': '1600'}
|
proposed
dict
|
always |
k/v pairs of parameters passed into module
Sample:
{'jumbo_max': '9000', 'jumbo_min': '8000', 'mtu': '1700'}
|
updates
list
|
always |
command sent to the device
Sample:
['interface 40GE1/0/23', 'mtu 1700', 'jumboframe enable 9000 8000']
|
This module is flagged as preview which means that it is not guaranteed to have a backwards compatible interface.
Hint
If you notice any issues in this documentation you can edit this document to improve it.